Confocal microscope: Leica SP8 (DM6 CS, upright)

  • Transmission bright field detector
  • Fluorescence filters, DAPI (emission: BP470/40); L5 (Emission: BP527/30); rhodamin (Emission: BP585/40)
  • motorized table, stitching detectors (1xPMT, 3xHyD)
  • laser lines/excitation wavelengths: 405nm, 488nm, 552nm, 638nm
  • deconvolution: HyVolution2
  • objectives: PL APO 10x/0.40; PL APO 20x/0.75 IMM, CorrR (water, glycerin, oil); FLUOTAR L 25x/0.95 W (water immersion); PL APO 63x/1.30 Glyc. CorrR (glycerin immersion); PL APO 63/1.2 W Corr. (water immersion)
  • notch filter (excitation): 445, 488, 514, 448/514, 488/552/638, 594, 445/594

Confocal microscope: Leica SP8 (CEPLAS, upright)

Flimm
detectors (2xPMT, 3xHyD)

 

 

 

Confocal microscope: Zeiss Meta 510 (inverted)

  • Excitation wavelengths: 458, 488, 514, 543, 633nm
  • HFT: 488; 458/514; 458/543; 477/543; 488/543; 514/633
  • HFT UV: 488/543/633
  • NFT: 515, 545, 570, 635VIS
  • LP: 475, 505, 530, 560, 585, 650
  • BP: 475-525; 505-530; 505-550; 530-600; 560-615; 585-615

Delta Vision RT (ChromaPhor)

 

  • type    wide field fluorescence microscope with reconstructive deconvolution
  • model    Inverse, IX71 Olympus
  • objectives    UPlan-flu 10x
  • UPlanSApo 20x
  • NeuFluor 25x Oil/W/G
  • UApo 40x Oil DIC
  • PlanApoN 60x Oil
  • UPlanSApo 100x Oil
  • camera    Coolsnap HQ (Photometrics)
  • filter    Standard set Dapi, FITC, TRITC, Cy 5, Live-cell set CFP, GFP, YFP, DsRed
  • light source    Hal 100, HG
  • chamber    heating Unit XL
  • software    softWorX
  • best used for    z-stack, time-lapse, tile-scan, multipoint, reconstructive deconvolution, ...

IX71 Olympus (Inverted)

type  wide field fluorescence microskop with reconstructive deconvolution
objectives
  • UPlan-flu 10x
  • UPlanSApo 20x
  • NeuFluor 25x Oil/W/G
  • UApo 40x Oil DIC
  • PlanApoN 60x Oil
  • UPlanSApo 100x Oil
camera Coolsnap HQ (Photometrics)
filter Standard set Dapi, FITC, TRITC, Cy 5, Live-cell set CFP, GFP, YFP, DsRed
light source Hal 100, HG  
chamber heating Unit XL
software    softWorX
best used for z-stack, time-lapse, tile-scan, multipoint, reconstructive deconvolution, ...

  
  
    
    
    
    

    

 

Olympus BX61 fluorescence microscope (in room 1.602)

stereo microscope (fluorescence)

  • Zeiss Stereo Discovery V8 (DAPI/GFP/RhDx)

Zeiss Axiovert 40 CFL

  • inverted light microscopy/fluorescence (DAPI, GFP, Ph1/2)

Zeiss ApoTome (fluorescence)

ESEM (scanning electron microscope)

  • separate conditions apply